(14 bar) Standard Setting
C 150 - 6000 psi (10,5 - 420 bar), 200 psi
(14 bar) Standard Setting
D 25 - 800 psi (1,7 - 55 bar), 200 psi (14
bar) Standard Setting
E 25 - 400 psi (1,7 - 28 bar), 200 psi (14
bar) Standard Setting
H 30 - 3000 psi (2 - 210 bar), 200 psi (14
bar) Standard Setting
J 25 - 1500 psi (1,7 - 105 bar), 200 psi
(14 bar) Standard Setting
W 100 - 4500 psi (7 - 315 bar), 200 psi (14
bar) Standard Setting
TECHNICAL FEATURES
Maximum pressure at port 3 should be limited to 3000 psi (210 bar).
Pilot operated valves exhibit very low dead-band transition between reducing and relieving modes.
Recommended maximum inlet pressure is determined by the adjustment range. Ranges D, E, N, and Q are tested with a 2000 psi (140 bar) maximum differential
between inlet and reduced pressure. Ranges A, B, and H are tested with a 3000 psi (210 bar) maximum differential between inlet and reduced pressure. Ranges C
and W are tested with 5000 psi (350 bar) of inlet pressure.
Pilot operated valves exhibit exceptionally flat pressure/flow characteristics, are very stable and have low hysteresis.
Pressure on the drain (port 4) is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
Pilot operated reducing, reducing/relieving valves by nature are not fast acting valves. For superior dynamic response, consider direct acting valves.
By controlling the pressure at the drain (port 4), the effective setting of the valve can be increased over the nominal valve setting.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge